YVP Series Electric Motor

Parameter:
  • Frame: 80-400mm.
  • Power: 0.37-630KW.
  • Frequency range: 3(5)-100HZ.
  • Rated frequency: 50HZ.
  • Rated speed: 1500rpm(4 poles)
  • Protection class: IP55.
  • Insulation class: F
  • Mounting type: Foot mount(B3), B5, B35, B14, B34.
  • Cooling method: IC416
Application:
Various operation systems by which speed-regulation is needed, such as metalllurgy, chemistry, textile, pumps, machine tools etc.
Features:
Step-less adjustable speed operation in a wide range, good performance of the system, energy saving, high level insulation material and special technological withstand high frequency pulse impact, separate fan for forced-ventilation.
Working condition:
The altitude not exceeding 1000m above sea level. the ambient temperature subject to seasonal variations but not exceeding +40℃ and not less than -15℃.
Type Power
(KW)
Rated Current
(a)
RT
N.m
constant torque frequency

variable HZ

constant torque frequency

variable HZ

80M1-4 0.55 1.5 3.5 5-50 50-100
80M2-4 0.75 2 4.7
90S-4 1.1 2.8 7
90L-4 1.5 3.7 9.5
100L1-4 2.2 5.1 14
100L2-4 3 6.8 19
112M-4 4 8.7 25.4
132S-4 5.5 11.4 35
132M-4 7.5 15.3 47.7
106M-4 11 22.1 70
160L-4 15 30.1 95.5
180M-4 18.5 35.4 117
180L-4 22 41.6 141
200L-4 30 55.9 191
225S-4 37 68.2 236
225M-4 45 82.5 286
250M-4 55 101 350
280S-4 75 132 477
280M-4 90 157 573
315S-4 110 191 700
315M-4 132 228 840
315L1-4 160 247 1019
315L2-4 200 342 1213

Parameter:
  • Frame: 80-400mm.
  • Power: 0.37-630KW.
  • Frequency range: 3(5)-100HZ.
  • Rated frequency: 50HZ.
  • Rated speed: 1500rpm(4 poles)
  • Protection class: IP55.
  • Insulation class: F
  • Mounting type: Foot mount(B3), B5, B35, B14, B34.
  • Cooling method: IC416
Application:
Various operation systems by which speed-regulation is needed, such as metalllurgy, chemistry, textile, pumps, machine tools etc.
Features:
Step-less adjustable speed operation in a wide range, good performance of the system, energy saving, high level insulation material and special technological withstand high frequency pulse impact, separate fan for forced-ventilation.
Working condition:
The altitude not exceeding 1000m above sea level. the ambient temperature subject to seasonal variations but not exceeding +40℃ and not less than -15℃.
Type Power
(KW)
Rated Current
(a)
RT
N.m
constant torque frequency

variable HZ

constant torque frequency

variable HZ

80M1-4 0.55 1.5 3.5 5-50 50-100
80M2-4 0.75 2 4.7
90S-4 1.1 2.8 7
90L-4 1.5 3.7 9.5
100L1-4 2.2 5.1 14
100L2-4 3 6.8 19
112M-4 4 8.7 25.4
132S-4 5.5 11.4 35
132M-4 7.5 15.3 47.7
106M-4 11 22.1 70
160L-4 15 30.1 95.5
180M-4 18.5 35.4 117
180L-4 22 41.6 141
200L-4 30 55.9 191
225S-4 37 68.2 236
225M-4 45 82.5 286
250M-4 55 101 350
280S-4 75 132 477
280M-4 90 157 573
315S-4 110 191 700
315M-4 132 228 840
315L1-4 160 247 1019
315L2-4 200 342 1213